[Home ] [Archive]    
:: Main :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 3, Number 1 (Jan-Mar 2016) ::
Nutr Food Sci Res 2016, 3(1): 51-56 Back to browse issues page
Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry
Maryam Zokaei, Marzieh Kamankesh, Saeideh Shojaei, Abdorreza Mohammadi
Assosiate profesor Associate professor of National Nutrition & Food Technology Research Institute, Faculty of Nutrition Science & Food Technology, Shahid Beheshti University of Medical Science, Tehran, Iran
Abstract:   (2204 Views)

Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry.

Materials and Methods: Important factors in the derivatization and measurement processes were optimized using the one-factor-at-a-time method. The peak areas were assumed as the GC-MS response to evaluate the extraction efficiency of acrylamide, and optimization for all tests was performed two times. Figures of merit of the proposed method were evaluated. The amount of acrylamide in four potato chips samples, obtained from the market in Tehran city, was determined using the proposed method.

Results: The optimum amounts of effective parameters, including derivatization temperature at 25oC, derivatization time (40 min), xanthydrol volume (40 µL), extracted solvent volume (500 µL) and pH=7 were determined. The figures of merit for the proposed method were at the ideal range. The maximum and minimum amounts of acrylamide in the chip samples were also measured.

Conclusions: The performance and reliability of proposed method as a simple, efficient and rapid method for determining acrylamide in potato chip samples were demonstrated.

Keywords: Potato chips, Acrylamide, Xanthydrol, Gas Chromatography-Mass Spectrometry
Full-Text [PDF 180 kb]   (1389 Downloads)    
Type of Study: Research | Subject: General
Received: 2015/10/2 | Accepted: 2016/01/5 | Published: 2016/01/5
Send email to the article author

Add your comments about this article
Your username or email:

Write the security code in the box >




DOI: 10.18869/acadpub.nfsr.3.1.51


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zokaei M, Kamankesh M, Shojaei S, Mohammadi A. Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry. Nutr Food Sci Res. 2016; 3 (1) :51-56
URL: http://nfsr.sbmu.ac.ir/article-1-127-en.html
Volume 3, Number 1 (Jan-Mar 2016) Back to browse issues page
Nutrition and Food Sciences Research
Persian site map - English site map - Created in 0.061 seconds with 793 queries by yektaweb 3463